FCCS – reactor/regenerator inferences
Should FCC reactor APC rely on inferential models?
Many FCC units operate flat out, maximizing conversion to LPG and LCN. Such operation makes sense where gasoline demand is high
But some refineries hydrotreat LCO into diesel oil, and they find it economical to increase LCO production by limiting FCC conversion. Under those circumstances FCCS is a tool for controlling reactor conversion at target
Reactor severity model
Severity = f(Temperature) * f(Contact Time)
* (Cat to Oil Ratio)
IE, severity is calculated from reactor conditions only, without knowledge of the feed.
Crackability definition
Conv * (100 – Conv) = f(Feed, Catalyst) * Severity
f(Feed, Catalyst) = Unmeasured crackability
Function of feed and catalyst conditions
Catalytic coke model
% coke make = g(Feed, Catalyst) * Severity
g(Feed, Catalyst) = Unmeasured coking tendency,
Also a function of feed and catalyst conditions